Outdoor Indoor Single Mode Multimode Fiber Optic Cable

Customization: Available
Application: Communication
Type: Singlemode Fiber or Multimode Fiber

Products Details

Basic Info.

Model NO.
Fiber Optic Cable
Material Shape
Glass Fiber
Certification
RoHS, CE, ISO9001
Brand
HNK or OEM
Sheath Material
PE, LSZH, PVC
Length
According to Requirement
Fiber Cores
According to Requirement
Transport Package
Wooden Wheel
Specification
RoHS
Trademark
HNK or OEM
Origin
Shenzhen, China
HS Code
85447000
Production Capacity
1000000m/Month

Product Description

HNK's ISO9001 certified factory in Shenzhen, China. HNK have generated a complete 
line of indoor and outdoor cable products in tight buffered and loose tube constructions. 

Excellent Performance & Competitive Price. Contact us now for more details!


Complied With OExceeds Standard

ITU-T G652.D                                      ITU-T G651.1 OM1 OM2 OM3 OM4 
ITU-T G657.A                                      IEC60793-2-10  type A1a.1/A1b OM1/OM2
IEC60793-2-10  type A1a.2 OM3        IEC60793-2-10  type A1a.3 OM4
ISO/IEC 11801 , ISO/IEC 24702         IEEE 802.3z Gigabit Ethernet
ANSI/TIA/EIA 568C.3                          ROHS Compliant Directive 2011/65/EU(ROHS2.0)
Outdoor Indoor Single Mode Multimode Fiber Optic Cable

Outdoor Indoor Single Mode Multimode Fiber Optic Cable
Optical Characteristics 

Of all the differences between multimode & singlemode fiber, the most fundamental differences are the 
size of the fiber's core and the associated attenuation or loss and bandwidth of the fiber. The smaller the 
core diameter, the higher the fiber's bandwidth and the lower the attenuation (loss in dB per kilometer). 
The fiber's attenuation and bandwidth are also dependent on wavelength. 

 
Singlemode was for high-speed long-distance transmission and multimode (in either the 50 µm or 62.5 µm 
core diameters) was used for lower speed short distance applications. Multimode 50 µm fiber had a lower 
cost and higher modal bandwidth than multimode 62.5 µm core fiber. Bandwidth is a measurement of the 
data-carrying capacity of the fiber. A higher bandwidth fiber carries more data. See table below.

 
Fiber Type Max. Attenuation 
(dB/km)
Min.Overfill Launch 
Bandwidth
 (Mhz.km)
Min.Gigabit Ethernet 
Link Distance
 (m)
Gigabit 10Gigabit
850nm 1300nm 1310nm 1550nm 850nm 1300nm 850nm 1300nm 850nnm
OM1 62.5/125µm ≤2.7 ≤0.6 - - ≥500 ≥600 275 550 -
OM2 50/125µm ≤2.3 ≤0.6 - - ≥500 ≥500 750 600 150
OM3 50/125µm ≤2.3 ≤0.6 - - ≥1500 ≥500 1000 600 300
OM4 50/125µm ≤2.3 ≤0.6 - - ≥3500 ≥500 1100 600 550
G652D 9/125µm - - ≤0.30 ≤0.18 - - - - -
G657A 9/125µm - - ≤0.35 ≤0.21 - - - - -

ANSI/TIA/EIA-598-B Standard Fiber Color Code
Fiber Number Fiber Color Fiber Number Fiber Color
Fiber 1 Blue Fiber 7 Red
Fiber 2 Orange Fiber 8 Black
Fiber 3 Green Fiber 9 Yellow
Fiber 4 Brown Fiber 10 Purple
Fiber 5 Gray Fiber 11 Pink
Fiber 6 White Fiber 12 Aqua
Fiber 13 and higher The color code is repeated with added black stripe or dash
Note: Fiber Tube color will be followed with same order.

Color Code
Outdoor Indoor Single Mode Multimode Fiber Optic Cable
Ordering Information

Part Number: OC-XX-ABCDCL

Ordering Guide
XX A B C D CL
Cable Type  Jacket  Fiber/Tube  Fiber Count Fiber Type(FXX) Jacket Color(CL)
please see the 
referrence above
1=PVC
2=LSZH
3=PE
01=01 Fiber/T
02=02 Fiber/T
...
11=11 Fiber/T
12=12 Fiber/T
No. Of Fiber 
004F,048F
OM1=62.5/125 OM1
OM2=50/125 OM2
OM3=50/125 OM3
OM4=50/125 OM4
G652D=9/125 G652D
G657A=9/125 G657A
As noted in 
Color code chart
Outdoor Indoor Single Mode Multimode Fiber Optic CableOutdoor Indoor Single Mode Multimode Fiber Optic CableOutdoor Indoor Single Mode Multimode Fiber Optic CableOutdoor Indoor Single Mode Multimode Fiber Optic CableOutdoor Indoor Single Mode Multimode Fiber Optic CableOutdoor Indoor Single Mode Multimode Fiber Optic Cable

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours